Type of
function |
GuardMagic FSM series |
|
FSM1 |
FSM2 |
FSM3 |
|
1 |
Power
source |
|
|
|
|
1.1 |
Main Power 9... 12 V DC |
+ |
+ |
+ |
|
1.2 |
External reserve battery (6,3 V , 1,2 A/h) |
+ |
+ |
+ |
| |
|
|
|
|
|
2. |
Inputs in general |
|
|
|
|
2.1 |
Logical inputs (ummary) |
4 |
4 |
4 |
|
2.2 |
Pulse inputs
(frequency or counter) |
2 |
2 |
2 |
|
2.3 |
Analog
input (analog fuel inputs) |
1 |
- |
- |
|
2.4 |
EIA-
485 interface (digital fuel sensors connection) |
- |
1 |
1 |
|
2.5 |
1-Wire interface |
- |
1 |
2 |
|
|
|
|
|
|
|
2. |
Main connection |
|
|
|
|
2.1 |
Total
fuel level sensors (fuel tank or fuel compartments
monitoring) |
1 |
3 |
7 |
|
2.2 |
Analog
fuel level sensor |
1 |
- |
- |
|
2.3 |
Fuel
level sensors with digital communication interface
EIA-485 (GuardMagic DFLS3, GuardMagic DFLS4 or with the
same communication protocol) up to: |
- |
3 |
7 |
|
2.4 |
Tamper
sensor or tamper circuit (logical) |
1 |
1 |
1 |
|
2.5 |
Customer
logical sensor or circuits |
3 |
3 |
3 |
|
2.6 |
Pulse
circuits or sensors (for example: Flow meter, engine RPM
etc.) |
2 |
2 |
2 |
|
2.7 |
Temperature sensors up to: |
- |
7 |
7 |
|
|
|
|
|
|
|
3. |
Main
technical data and
function |
|
|
|
|
3.1 |
"Fuel
resolution (on EIA-485 bus, depend of type of sensors)
up to levels: |
- |
1024 or
4096
|
1024 or
4096
|
|
3.2 |
Functionality: operation mode, programming mode |
- |
+ |
+ |
|
3.3 |
Operation mode: Real Time, Packet, logger |
+ |
+ |
+ |
|
3.4
|
Data
transmitting: GSM/GPRS 900/1800/1900 or Quad |
+ |
+ |
+ |
|
3.5 |
GPRS
connection to monitoring station: main or reserve |
+ |
+ |
+ |
|
3.6 |
Internal
memory (to store collected data) |
+ |
+ |
+ |
|
3.7 |
Automatic storing collecting
information if GPRS or Internet
connection is absence. |
+ |
+ |
+ |
|
3.8 |
Automatic transmitting (or
storing) data from fuel level sensors
and external sensors |
+ |
+ |
+ |
|
3.9 |
Connection to temperature
sensors |
- |
+ |
+ |
|
3.10 |
Staff
identification |
- |
- |
+ |
|
3.11 |
Automatic activation for
data sending (alarm data):
Tamper;
Logical inputs activation;
Fueling or Fuel drain over;
Main power alarm (if reserve battery connect);
Pulse signal starting. |
+ |
+ |
+ |
|
3.12 |
User programming periodicity
of data sending |
+ |
+ |
+ |
|
|
|
|
|
|
|
4. |
Additional |
|
|
|
|
4.1 |
Main Power control (if
reserve battery connecting) |
+ |
+ |
+ |
|
4.2 |
Possibility connection to
pulse flow meter and/or engine RPM
sensor (pulse counting) |
+ |
+ |
+ |
|
4.3 |
Base station time
synchronization |
+ |
+ |
+ |
|
4.4 |
Available edition:
Standard (inside application)
Dust and water resistance (outside application, IP 65
plastic enclosure)
Anti vandal, dust and water resistance (outside