Fuel Consumption Monitoring Vehicle Monitoring Fuel Tanker Monitoring. Cargo Fuel Tank Monitoring Remote Fuel Storage Tank Monitoring Monitoring and Reporting
 
    
 
HOME
      
    NEWS
    CONTACT
    ABOUT TECHNOLOGY
  - about GPS
  - about M2M
   GPS ON TRANSPORT
  - introduction
     - "Off-Line" Monitoring
     - "On-Line" Monitoring
   SOLUTION
  GPS passive monitoring
  - GPS-GSM monitoring
  - Fuel Monitoring
  - Tanker monitoring
  - Fuel Storage monitoring
  - Diesel Generator monitoring
  - GPS-Radio monitoring
    PRODUCTS
  - products list
  - documentation, leaflets
   BY APPLICATION
          
    DOWNLOADS   
   DISTRIBUTORS LIST  
   ORDER PROCEDURE  
   USEFUL LINKS 
               
   COOPERATION:
  - for distribution (distributors)
  - for integrators, providers
 
 
 
                Fuel Saving
 Control Fuel Consumption

 

Saving Fuel,- Increase Your Profit

"GuardMagic fuel saving system" is repaid  in 3-6 weeks, primarily due to fuel theft (drain) and fuel fraud decrease. In practice, this means ...

  
 
PRODUCTS
  
 
        
     Fuel Level Sensors
 
 
 
GuardMagic FLPa/V5;  GuardMagic FLPa/V9
Electronics Fuel Level Sensor with Analog Output
 
ABOUT
 
 
       ABOUT
 

 

 

GuardMagic FLPa/V5, GuardMagic FLPa/V5:
 
the special electronic fuel level probe  for the fuel monitoring and fuel measurement system (stationary and transports).
Available length from 200mm and up to 4000mm (ordered).
Analog output.
 
GuardMagic FLPa (FLP) can be installed in any type of motor vehicles, tractors, construction and agricultural machines or diesel-electric locomotives.
 
GuardMagic FLPa has an analog output
 
main data:
 
Power supply:
 
  • 8 ... 30 V
Consumption power:
 
  •  < 0,2 watt
Operation principle:
 
  • capacitive
GuardMagic FLPa/V5:
Output
  • Analog; 0-4,5 V
GuardMagic FLPa/V9:
Output
  • Analog; 0-9V
Probe length :
  • factory order
L1 version
200 mm - minimum;
1100 mm- maximum.
L2 version
1200 mm - minimum;
1700 mm - maximum.
L3 version
1800mm - minimum;
4000 mm - maximum.
Acceptable reduced error range of fuel level metring:
  • +/-  1%
Dimension:
  •  L x70mm x70mm
(L = 200mm .... 4000mm)
Operation:
Working mode
 
  • continuous
Working pressure
 
  • atmospheric
Temperature
  • -40...+80
Humidity:
  • <95% (+40 C)
           
Fuel level sensors use capacitive technology to accurately sense the level of most fuel types. With no moving parts or floats.
Such type of sensors also are ideal for use in harsh environments, where the temperature and vibration extremes make other types of sensor unsuitable.
 
    